Product or Service

Portable Ultrasonic Flaw Detector

Profile:Manufacturer - Producer|Ref:PSL130135YH | Country: China | Currency: | Export: No

Currency :
incoterm : fob
country : China

Range: 0 to 9999 mm, at steel velocity
Material Velocity: 1000 to 9999m/s
Display Delay: -20 to 3400 µs
Probe Delay/Zero Offset : 0 to 99.99µs
Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
Test Modes: Pulse echo, dual element and thru-transmission
Pulser: Tunable Square Wave Pulser
Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
Pulse Energy: Low, Medium and High
Damping: 100, 200, 400 ohms
Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
Gate Monitors: Two independent gates controllable over entire sweep range
Rectification: Positive halfwave, negative halfwave, fullwave, RF
System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier
Accuracy +/-1 dB.
Reject (suppression): 0 to 80% full screen height
Units: Inch or millimeter
Transducer Connections: BNC or LEMO
Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
Dimensions: 263H×170W×61D mm
Operating Temperature: -10℃ to 50℃
Storage Temperature: -30℃ to 50℃

Hi-resolution (320×240 pixels) multi-color TFT LCD with 4 user-selectable
brightness control provides high contrast viewing of the waveform from bright,
direct sunlight to complete darkness.
The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an
“analog look” to the waveform providing detailed information that is critical in
many applications including nuclear power plant inspections.
Up to 9999 mm in steel. suitable for use on large work pieces and in
high-resolution measurements.
Pulse Energy selectable among Low, Medium and High.
Pulse Width tunable from 0.1µs to 0.5 µs to match the probes with different
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments.
Damping selectable among 100Ω、200Ω and 400Ω for optimum probe
Test Modes include Pulse echo, dual and thru-transmission
Sampling:10 digit AD Converter at the sampling speed of 160 MHz
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth: 0.5MHz to 15MHz capability with selectable frequency
ranges (automatically set by the instrument) to match probe for optimum
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked.
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory of 100 channel files to store calibration set-ups
Memory of 1000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.

Information Stock : Product in stock


No attachments

Contact the company