Unit ELEVATOR is a manufacturer and supplier of machine part lift, load lift, lift at low speed in China. Our machine room elevator or lift villa is low noise and installation.
Main specification of elevator machine room
400 kg capacity 1600 kg-
Vitesse:1.0M/s-2.5M/s
Machine: UNT09
Controller: U - Con L2000/3000/4000
door: door of VVVF drive operator
car control panel: U-CF100
infrared gate: curtain protection
1.Operatior automatic: the lift operates automatically and stops, opens/closes the door according to the specified command
- Operation by the operator: the lift operates automatically and stops, manually close the door according to the specified drive operation
3.Revision: under conditions of repair and inspection, races of elevator at the speed of inspection by buttons upwards of slowdown in operation "slow" door-opening
Automatic 4.Haut: when the elevator is electrified and the car is in the door zone, it will open the door automatically
5.Porte - closed automatic time delay: after the car door was opened fully, she keeps the door open State, it closes automatically the door after time delay
6.Call for the opening of this floor: when the elevator closes the door or it does not start but has closed the door, when there is call external from this landing, it will reopen the door curtain protection.
7.Optique: when the light curtain is embarrassed, it immediately stops door-a firm action and automatically opens the door.
8.Surcharge no door-a closed: it does not close the door in the overload, and it is light overload lamp.the buzzer rings, it shows the CZ or overload in the car and does not start the lift
9.Pleine load direct operation: when he reaches the rated load, it just meets the internal selection instead of calling external lighting
10.Automatique and fan control: at the time stipulated, if the lift is not receiving no control travel, lighting will turn off automatically, it opens automatically in the protection command
11.Contactor: the system can detect whether the action of motor circuit contactor is reliable or not, if any abnormal condition occurs, it will stop the trip to lift protection of the contactor
12.Principal: after the elevator runs door - closed the command, if the door was not closed in time stipulated, it will reopen the door and then the close yet
13.Landing floor, direction in the car display: it shows the floor landing of the elevator, the direction where the lift will travel in the car
14.Direction chosen by the driver: the current direction is determined by the directive of the diagnostic driver
15.Trouble: when there is some