ETCO2+SPO2 Patient Monitor 3.5 Inch

Profil : Fabricant - Producteur | Réf : PSL122050YH | Pays : China | Devise : USD | Incoterm : FOB | Export : | Import :

RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements.

RSD2001A (standard)can monitor vital signals correlating to SpO2 and CO2. It integrates parameter measuring modules and display in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. The LCD of high resolution and bright LED display provides clear view of 2 waveforms,SPO2,PR,EtCO2,InCO2,Respiration rate.

Specifications
Display
Messages
2 Waveforms
2 indicator lights
2 Sound Mode corresponding Alarm Mode
Device
1 dot matrix LCD size 3.5", resolution 256X120
5 digital LED windows

CO2
Method Infra-red Absorption Technique
Measuring mode Sidestream
Side-stream mode sampling gas flow rate
100, 150, 200 ml/Min (option)
Measuring range
CO2 0~99 mmHg
INSCO2 0-99 mmHg
AwRR 0~150 rpm
Resolution
CO2 1 mmHg
INSCO2 1mmHg
AwRR 1 rpm
Accuracy
CO2
2 mmHg,0 ~ 40 mmHg
5% of reading,41 ~ 76 mmHg
10% of reading, 77 ~ 99 mmHg
AwRR 2 rpm
Actualization interval about 1 Sec.
Start-up Time < 10 sec
Rise Time 240 msec (10% to 90 %)
Delay Time 1.12 seconds maximum with 7| length, 0.055|| ID.
Sampling line at 175 ml/min
Alarm range
CO2 0 ~ 99 mmHg
InsCO2 0 ~ 99 mmHg
AwRR 0 ~ 150 rpm
Suffocation Alarm Delay
AwRR 10 ~ 40 Sec

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1Sec
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy 2bpm
Alarm Delay 10 Sec.

Recall
Trend Recall
8 to 96hours all parameters result.
NIBP Measurement Recall
50 NIBP measurement data.

Signal Interface
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50
Signal Delay < 20 mS

Battery
Rechargeable 4.0 A/Hr 8.4V Li-ion battery
Operating time under the normal use and full charge greater than 4 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is 4 hours

Environment
Temperature
Working 0 ~ 40 degrees
Transport and Storage -20 ~ 60 degrees
Humidity
Working 30% - 85 %
Transport and Storage 30% - 93 %(no coagulate)
Altitude
Working -500 to 4,600m
Transport and Storage -500 to 13,100m

Power Supply
100/250 VAC, 50/60 Hz (for adapter)
Pmax=30VA
Dissipation
Working Less than 3W
Power-off Less than 0.1W

Size and Weight
Size 318 x 152 x 264 mm
Weight 5.5 kg

Type de l'annonce : Offre de produit

Référence de l'annonce : PSL122050YH

Référence de l'annonceur : REF-94367

Devise : USD

Incoterm : FOB

Quantité minimum d'achat : 5

Catégorie: Other radiation measurement instruments

Mots clés : patient monitor | monitoring | fetal monitor

Autres annonces de l'annonceur qui peuvent vous intéresser

Pourquoi importer avec Golden-Trade ?

Acheter à l'international n'a jamais été aussi simple et sûr :

Un interlocuteur unique

Un interlocuteur unique
du début à la fin

Une interface simple

Une interface simple
pour suivre vos opérations

Une gestion de bout en bout

Logistique "porte à porte"
on vous livre où vous le voulez

Une police d’assurance garantie de bonne fin

Garantie de bonne fin
jusqu'à 7,5 millions €

Crédit import

Crédit import
Achetez maintenant et payez dans 180 jours max *sous conditions