TRG 8020 can be used for measuring level or interface with 4-20mA standard current signal output. The measuring accuracy is not affected by change of density or dielectric constant of medium (in the setting range). It is easy operating and maintenance. It only needs to be entered configuration data into the instrument and no need to change the liquid level at field. So, GWLF is a new type of level (interface) measuring instrument.
Output signal: 4 ~ 20mA or 4 ~ 20mA + HART, applicable within 3.8 ~ 20.5mA
Resolution: Analog: 0.01mA, Display: 1mm
Accuracy: 5mm or 0.1% FS for coaxial probe
Range: 600mm ~ 6000mm or 1000mm ~ 22000mm
Load resistance: Max. 650Ω(24VDC)
Damp: 0-32s adjustable
Diagnostic alarm: 3.6mA, 22mA, hold (Note: when both HART protocol and field indicator are selected, 3.6mA diagnose is not available.)
User interface: 3 keys, LCD or HART communication
Ambient temperature: -40°C ~ 70°C (LCD operating temperature: -20°C ~ 70°C)
Power supply inlet: M20×1.5 or RC1/2 (female thread)
1/2″NPT (female thread)
3/4″NPT (female thread)
Enclosure material: Aluminum
Explosion-proof: Intrinsically safe Ex ia II CT2-T6
Explosion isolation + Intrinsically safe Exd (ia) II CT2-T6