Place de provenance : GOLDEN TRADE INTERNATIONAL

Omron Power Supply S8TX Series S8TS-06024F-E1

Profil : Association | Réf : PSL313386YH | Pays : China | Devise : | Incoterm : | Export : | Import :

Basic Block , Connector Terminal Type , Input 100 to 240 VAC , Output 24 V 2.5 A
Power rating 60 W
Efficiency 80% TYP. (At rated input, 100% load)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.0 A Max. (At 100 VAC input)0.5 A Max. (At 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.35 mA Max. (At 100 VAC input)0.7 mA Max. (At 240 VAC input)
Inrush current 17.5 A Max. (At 100 VAC input (For cold start at 25 CEL))35 A Max. (At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range 22 to 28 V (With V. ADJ)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 3.5% Max. (Single operation, 0 to 100% load)2% Max. (Single operation, 10 to 100% load)5.5% Max. (Parallel operation, 0 to 100% load)3% Max. (Parallel operation, 10 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.5 A
Start up time 1000 ms Max. (100/200 VAC, rated input)
Hold time 20 ms Min. (100/200 VAC, rated input)
Overload protection 105% to 140% of the rated output current (Single operation), 100% to 140% of the rated output current (Parallel operation)Inverted L voltage drop, Automatic reset
Overvoltage protection Operated at 120 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 1 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max.
Parallel operation Yes (Up to 4 Blocks)
N+1 redundant system Yes (Up to 5 Blocks)
Series operation Yes
Applicable standard (UL) Standard No.: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class AEMS: EN61204-3
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity

Type de l'annonce : Offre de produit

Référence de l'annonce : PSL313386YH

Référence de l'annonceur : REF-140229

Catégorie: Coal gas

Mots clés : inverter

Autres annonces de l'annonceur qui peuvent vous intéresser

Pourquoi importer avec Golden-Trade ?

Acheter à l'international n'a jamais été aussi simple et sûr :

Un interlocuteur unique

Un interlocuteur unique
du début à la fin

Une interface simple

Une interface simple
pour suivre vos opérations

Une gestion de bout en bout

Logistique "porte à porte"
on vous livre où vous le voulez

Une police d’assurance garantie de bonne fin

Garantie de bonne fin
jusqu'à 7,5 millions €

Crédit import

Crédit import
Achetez maintenant et payez dans 180 jours max *sous conditions