- Thermostatic
Size: DN15 Flow Rate after mix:0-1M³h Cold water Temperature:10-20 Deg C(Manual Adjusting) Fixed Temperature - System Design Solution
The hot water temperature control use the instant heating method, the heat tank volume is 1 M³,Set the heat boiler, the temperature ranges from 60-80 Deg C.
The warm water after mixture back to the heat tank, the remain water through the bleeding drain out
The cold water through one water tank as buffer, directly make up for tap water
The valve required cold water and hot water pressure through the convert frequency automatic control, adjusting stable ,fast and convenient
The flow meter has three sets, including cold water, hot water and mixed water flow rate
The valve installation use the start fixture, by fast clamping method
The valve back pressure adjust by the manual valve - Electrical Design Solution
Use the Siemens PLC and data adjusting gauge to control
By the adjusting gauge automatically control the temperature and pressure, the PLC collect the temperature, flow rate and pressure, and display and judge. Automatically control movements status all datas will be read through the touch screen, operation system abnormality and seting times reaches, the alarm will alarm immediately, user can print out the testing data, the testing accuracy is 100%, the products loading and discharge are easy and simple.