I. Technical features
Suitable Media: conductive liquid
Instrument Accuracy: ±1.0%、±0.5%
Measure Range Ratio: 150:1
Diameter Range: DN10—DN1200mm
Instrument Feature: highly corrosive media measurable
Electrode Materials: 316L, titanium, hastelloy, tantalum, platinum(optional)
Liner Materials: rubber, PE, PTFE(optional)
II. Technical Parameters
Nominal Diameter(mm): Customized
PTFE pipe liner: DN10~DN600
Rubber pipe liner: DN40~DN1200
Flow Direction: positive, negative, net flow
Measure Range Ratio: 150:1
Repeatability error: ±0.1% Measured value
Accuracy Class: ±0.5%, ±1.0%
Medium temperature measured:
General rubber liner: -20~+60℃
High-temperature rubber liner: -20~+90℃
PTEF liner: -30~+100℃
High-temperature PTEF liner: -20~+180℃
Rated working pressure: (High pressure customizable)
DN6-DN80:≤1.6MPa
DN100-DN250:≤1.0MPa
DN300-DN1200:≤0.6MPa
Flow rate range: 0.1-15m/s
Conductivity range: Fluid conductivity measured≥5μs/cm
Current output:
Load resistance 0~10mA:0~1.5kΩ
4~200mA:0~750 kΩ
Digital Frequency Output: 1~5000HZ
External Power: ≤35V
Collector current: ≤250mA
Power supply: AC220V or DC24V
Straight length: Upstream≥5DN,downstream≥2DN
Connection mode : Flange joint
Explosion-proof class: mdIIBT4
Protection class : IP65, up to IP68
Ambient Temperature : -25~+60℃
Relative Humidity : 5%~95%
Total power consumption : <20W